Configuring a Modbus Plus Network in Concept with Peer Cop
870USE10110 July 2004 335
Defining References for the Supervisory PLC
Overview At this point, we will attach the Concept programming panel to the ATRIUM 180-
CCO-111-01 supervisory PLC at Modbus Plus address 1 and set up Peer Cop
screens to handle the M1 CPUs at addresses 2 and 3.
We know that the M1 at Modbus Plus address 2 is sending eight words of specific
output to the supervisor and that the M1 at Modbus Plus address 3 is sending 16
words of specific output to the supervisor. The supervisor will receive this data as
specific inputs.
We also know that the supervisor is sending 10 words of global data, parts of which
will be received by both of the M1 CPUs.
Defining the
Specific Inputs
First we will define the specific inputs to be received by the supervisor.
Step Action
1 Click on the Specific Input... button.
Result: The Specific Input dialog box appears.
2 Enter the references for each CPU on the appropriate source line, as shown
below. Then click <OK>.
Specific Input
OK
Cancel
Help
Range:
Dest. Node Source Ref. Length Bin/BCD
1
2 400001 8 BIN
3 400020 16 BIN
4
5
6
7
8
9
10
11
12